At first I thought there had been a mix up as I required the service manual for the cassette unit and the one supplied was for the CD unit. However when I scrolled further down I realised that both had been scanned together! This enabled me to dismantle and repair the cassette unit as intended and I also have a copy of the manual for both the CD and graphic equaliser units should I ever need them. Thanks very much for a great service.
;
Excelent service, the manual is complete, very cheap and fast
Alberto
;
The item received was as described, as expected. I was pleased with the order. Thank you.
;
Superb rendition. Drawings (schematics) complete and unabridged. I do a great deal of vintage audio restoration. Documentation is essential for successful repairs. I have found sources over the years that offer good documentation, but rarely all that is necessary. Owner's Manuals has filled that void with complete and legible documentation. They have narrowed my "favorites" to a more manageable collection. This Denon manual in particular contained the latest revisions level, and offered alterations favorable to updating the item. The Illustrated Parts Breakdown (IPB) was well enough detailed to simplify part symbols and physical locations. You will not be disappointed!
;
Clear and concise. Saved me a lot of time and money.
13. CCD white dot defect compensation [Conditions] � With the lens shutter being closed, read the defect of CCD pixels. Then, make the correction data and rewrite the data by the following procedure. Correct the upper level of defective 2000 pixels from the brightest number of CCD pixels.. [How to] � Double-click on "DscCa1Di.exe". � Select "CCD Defect" from Test menu of Calibration Software and click the "OK". Refer to <FIG-1>. � After adjustment, the adjustment value will appear on the screen. Refer to <FIG-2>.
VAA36001-R.3667.A
<FIG-2>
CCD Defect CCD Black
<FIG-1> 14. CCD black dot/white dot defect adjustment [Conditions] � Fix the camera so that only the white part of the pattern box should be displayed on the screen. Note) Do not allow outside light to enter in. (Use a blackout curtain.) � Set the camera and the viewer surface of pattern box to be perpendicular. (Do not allow outside light to enter in as much as possible.) � With the lens shutter being opend, read the defect (black dots) of CCD pixels. Then, make the correction data and rewrite the data by the following procedure. Correct the upper level of defective 48 pixels (black dots in bright place) of CCD pixels. [How to] � Double-click on "DscCa1Di.exe". � Select "CCD Black" from Test menu. Refer to <FIG-1>. � After adjustment, the adjustment value will appear on the screen. Refer to <FIG-3>. � Click "OK".